Quick Start Guide for First-Time Users of the MonoCell
MonoCell
MonoCell Components
Tinn includes a hardware adjustment from H/W 1.04r to ensure stable compatibility with single-cell sensors (KN10, KN10-HT150).
Earlier versions (1.02r and prior) are not compatible—please check your controller’s H/W version before use.
If you are using an older unit, you will need to purchase a unit with H/W 1.04r or later to use single-cell sensors.
How to Install and Use MonoLAB Software
MonoLAB is the software provided by MonoCell.
Follow the steps below to install and use it with ease.
1. Software Download
Click the download button to download the software.
※ Membership registration is required for the download.
2. Run the Installation File
Follow the installation guide to complete the installation.

※ During the installation, FTDI drivers and .NET Framework will be installed. Both must be installed.
In most cases, .NET Framework is already installed, so you may receive a message indicating it is already installed.
3. Connect the Tinn Controller and Launch MonoLAB
Connect the Tinn controller to your PC using a USB cable.
When you launch MonoLAB, the software will automatically detect the connected device port.
※ If multiple devices are connected, the software may not connect to the intended device.

4. Create a Project File
Click the "Create New Project" button and enter a name for your project.
Then click the "Save" button to create the project.
※ Project files are saved in the .mlp format.


5. Connect the Sensors
Check the controller's connection ports and determine where to connect each sensor.
– You can connect up to 10 sensors in total.

6. Exit 'Edit Mode'
Once the main screen of the program appears, switch Edit Mode under the Setup menu to "Off".
When Edit Mode is turned "On", you can configure sensor connections, names, and layout.
However, real-time analysis is not available in this mode.
For more details about sensor setup mode, please refer to the MonoCell User Manual.

7. Start Real-Time Analysis
After connecting the sensors to the controller, check the central monitoring screen to ensure sensor output is being received.
By default, sensors 1 through 10 are placed in the first row of a 10×10 matrix layout.

This completes the installation and basic setup of MonoCell.
For more information, please refer to our Manual, FAQ, and Portfolio sections on the website,
or visit our YouTube channel.
If you have any other inquiries, please leave a message through the URLs below, and we will respond promptly.
For product inquiries: https://www.kitronyx.com/contact
For technical support inquiries: https://www.kitronyx.com/support_request
With the purchase of a controller, a controller test board is provided to check for any malfunctions.
For detailed information, please refer to the attached Controller Test Board User Manual.
If you have any other inquiries, please leave a message through the URLs below, and we will respond promptly.
For product inquiries: https://www.kitronyx.com/contact
For technical support inquiries: https://www.kitronyx.com/support_request
controller test board manual_240715.pdf
135KBThe controller test board will be provided from the new controller package starting in April 2024.
Please inquire if you need a controller test board.
Link to how to use the controller test board
If you have any other inquiries, please leave a message through the URLs below, and we will respond promptly.
For product inquiries: https://www.kitronyx.com/contact
For technical support inquiries: https://www.kitronyx.com/support_request
Currently, there is no controller available for high-speed measurement, but custom development is possible.
In a previous case, we tested ball drops with high-speed measurement at 600Hz.
Please refer to the YouTube video below.
For custom development and product inquiries, please contact us through the information provided below.
If you have any other inquiries, please leave a message through the URLs below, and we will respond promptly.
For product inquiries: https://www.kitronyx.com/contact
For technical support inquiries: https://www.kitronyx.com/support_request
The SFCXXXXCX products can be cut for use based on the lower left section as shown in the image.
For more details, please refer to the demo videos on cutting sensors.
Latest Cutting Sensor Demo Video
Cutting Sensor Demo Video
We can customize the product to your desired shape for an additional fee.
Please contact our sales team for assistance.
Sales@kitronyx.com
If you have any other inquiries, please leave a message through the URLs below, and we will respond promptly.
For product inquiries: https://www.kitronyx.com/contact
For technical support inquiries: https://www.kitronyx.com/support_request
The recommended operating temperature for the sensor is room temperature (23±5°C).
Using the sensor above this temperature range may result in decreased measurement accuracy and potential damage to the sensor.
The pressure range varies by product, so please refer to the detailed product pages for specific information.
If you need to use pressure outside the specified range, we can adjust the product through customization.
Please contact our sales team for assistance.
Sales team contact information
E-mail : Sales@kitronyx.com
If you have any other inquiries, please leave a message through the URLs below, and we will respond promptly.
For product inquiries: https://www.kitronyx.com/contact
For technical support inquiries: https://www.kitronyx.com/support_request
For size information of standard sensors, please refer to the table below.
Custom manufacturing in required sizes is also possible.
If you need custom production, please contact our sales team (Sales@kitronyx.com)
If you have any other inquiries, please leave a message through the URLs below, and we will respond promptly.
For product inquiries: https://www.kitronyx.com/contact
For technical support inquiries: https://www.kitronyx.com/support_request
If pressed with a soft object like a hand at a pressure of 1 kgf/cm², the sensor's lifespan is over 50,000 times.
When pressed with a metal object at a pressure of 10 kgf/cm², the approximate lifespan of the sensor is between 500 to 1,000 times.
* The number of uses may vary depending on the usage environment (pressure conditions, shape, etc.)
The main reason for sensor damage is not exceeding the number of uses,
but rather carelessness such as external damage due to improper usage methods and storage management.
If you have any other inquiries, please leave a message through the URLs below, and we will respond promptly.
For product inquiries: https://www.kitronyx.com/contact
For technical support inquiries: https://www.kitronyx.com/support_request
Our product does not support waterproof functionality,
so we recommend using it in a dry condition.
If you have any other inquiries, please leave a message through the URLs below, and we will respond promptly.
For product inquiries: https://www.kitronyx.com/contact
For technical support inquiries: https://www.kitronyx.com/support_request
Our sensors are of the film type and can be bent for use.
However, noise may occur depending on the degree of curvature, so testing is required to confirm applicability.
Please check the related video at the link below.
If you have any other inquiries, please leave a message through the URLs below, and we will respond promptly.
For product inquiries: https://www.kitronyx.com/contact
For technical support inquiries: https://www.kitronyx.com/support_request
This phenomenon is due to the viscoelastic properties of the material composing the sensor,
causing the output value to change over time under the same pressure.
Because of this characteristic, we recommend performing measurements within a short period (up to 5 minutes) for more precise results.
For more detailed information, please refer to the following content.
If you have any other inquiries, please leave a message through the URLs below, and we will respond promptly.
For product inquiries: https://www.kitronyx.com/contact
For technical support inquiries: https://www.kitronyx.com/support_request